Product Center



CES2000 Industrial Carrier Ethernet Switches

8 Gigabit TX ports+8 100/1000M SFP slots+1 SD card slot
  • Overview
  • Specification
  • Ordering Information
MRD™ CES2000 series switches are specially designed for carrier network access and aggregation applications. As an all-in-one device, CES2000 provides network access and aggregation, power supply and time synchronization solutions. By providing GPS, PTP1588V2, POE and other features, CES2000 can accomplish the network access and backhaul for commercial buildings, transportation hubs, malls, office buildings, business offices and various complex applications. With hardware-based algorithm, the patented MRD-RING® (MRDcom Real-Time Ring) technology ensures less than 5ms self-recovery time of every node and less than 50ms self-recovery time of the network. CES2000 also supports MRD-RING® Media Redundancy Protocol (compliant with IEC62439) and PRP/HSR (compliant with IEC62439-3).CES2000 series utilize half-rack installation design and support up to 8 Gigabit TX ports (802.3af/at), 8 100/1000M SFP slots and 1 SD card slot.
 
 
Features and Benefits
 
● Support PTP 1588V2 time synchronization
● Support Sync-E, PTP, ZTP, CCM, MEF E-LAN, MEF E-TREE and Q-in-Q
● Support MRD-RING® network redundancy for < 50 ms recovery time
● Support multiple POE ports, compliant with 802.3af/at standards
● Built-in 130W power supply for POE models
● Any two ports can establish a self-recovery ring and support multiple independent self-recovery rings
● With functions of data packet dropout protection and quick recovery from network failure
● Provide bandwidth service with different levels in Ethernet service by speed limiting and traffic shaping in QoS of layer 2
● Provide a full set of professional network management, monitoring and alarm system and support OPC
● Support Dying gasp and one relay alarm output
● Dual redundant power inputs design for DC models
● -40 to 70°C wide operating temperature range (non-POE models)
Software Functions 
Management Mode: Web, serial port, STD-17 MIB-II, STD-58 SMIv2, STD-59 RMON, STD-62 SNMPv3, SNMPv2c, SNMPv1, RFC2668 MAU, RFC2925 Ping MIB, MRD Private MIBs
Diagnosis Mode: Indicator light, journal file, relay, RMON, port mirroring, TRAP
Redundancy: MRD-RING®, HSR, PRP, MSTP, RSTP, port trunking
Time Synchronization: IEEE1588, NTP, SNTP
Others: IPv4/IPv6 multicast, storm control, MC/BC protection, support Jumbo Frame

Technical Specification
Standard IEEE 802.3 CSMA/CD method and physical Layer specifications
IEEE 802.1p Priority Queuing
IEEE 802.1q VLAN tagging
IEEE 802.1d Spanning Tree Algorithm
IEEE 802.1w Rapid Spanning Tree
IEEE 802.1s Multiple Spanning Tree
 IEEE 802.3ac VLAN Tagging
 IEEE 802.1x Authentication
 IEEE 802.3ad Link Aggregation
 IEEE 802.3x Flow Control
 IEEE 802.3 Ethernet
IEEE 802.3u Fast Ethernet
IEEE 802.3z Gigabit Ethernet
 IEEE 802 Networks
RFC 768 UDP
RFC 791 IP
 RFC 792 ICMP
 RFC 793 TCP
 RFC 826 ARP
 RFC 854 Telnet Client & Server
 RFC 951 BootP
 RFC 862 Echo Protocol
RFC 863 Discard Protocol
RFC 867 Daytime Protocol
RFC 868 Time Protocol
RFC 919 Broadcasting Internet Datagrams
RFC 922 Broadcasting Internet Datagrams in the Presence of Subnets
RFC 1027 Using ARP to Implement Transparent Subnet Gateways agent ARP
RFC 1042 Standard for the Transmission of IP Datagrams over Networks through IEEE 802 network IP Data Packet Transmission Standard
 RFC 1059, 1119 NTPv1/2
 RFC 1112 IGMP
 RFC 1122 Host Requirements
 RFC 1166 Internet Numbers
 RFC 1191 Path MTU Discovery
 RFC 1256 ICMP Router discovery protocol
 RFC 1305 NTPv3
RFC 1542 Bootstrap Extensions & DHCP
IEEE 1588v2 with one-step clock support
 RFC 1866 HTML
 RFC 2068 HTTP
 RFC 213 DHCP Server
 RFC 2132 DHCP Options and BOOTP Vendor Extensions
 RFC 2138 RADIUS
 RFC 2139 RADIUS Accounting
 RFC 2236 IGMPv2
 RFC 2474 DiffServ Precedence
 RFC 2475 DiffServ Core and Edge Router Functions
 RFC 2597 DiffServ Assured Forwarding
 RFC 2598 DiffServ Expedited Forwarding
 RFC 2644 Directed Broadcasts
RFC 2865 Remote Authentication Dial In User Service (RADIUS)
RFC 3046 DHCP Relay Agent Information Option
RFC 3084 COPS-PR
RFC 3140 PHB Identification Codes
RFC 3222 Forwarding Information Base (FIB)
GVRP GARP
 MVC
 SSH2 Secure Shell 2
IGMP snooping
 SNMPv3
Hardware Description Backplane Bandwidth:  52 Gbps
CPU:MIPS
Switch Architecture:Store-and-Forward
MAC Table Size: 8K (maximum)
Memory:128M
Exchange Rate:1, 488, 000 pps/1000M ports
Physical Characteristics MTBF:> 800, 000 hours
Storage Temperature:-40°C~ 85°C
Operating Temperature:-40°C~ 70°C
Ambient Relative Humidity:5% ~ 95% (non-condensing)
Dimensions:1U; depth: 150mm             
Protection Grade: IP40
Weight: 3.7KG (Maximum)
Power Consumption: 31W (Maximum)
Testing       Vibration:  IEC 60068-2-6
Shock:       IEC 60068-2-27
Freefall:     IEC 60068-2-32
Circuit Board: Approved by IPC
EMI:      FCC 47 CFR Part 15 Class A
                EN55022 Class A
EMS:       IEC (EN ) 61000-4-2, Class 4
                IEC (EN ) 61000-4-3, Class 4
                IEC (EN ) 61000-4-4, Class 4
                IEC (EN ) 61000-4-5, Class 4
                 IEC (EN ) 61000-4-6, Class 4
                IEC (EN ) 61000-4-9, Class 4
Industrial Certification Product Safety:   CE.CB.IEC.IECEE
                     IEC/EN60950-1
                     FCC Part 15 Subpart B Class A
                    IEC/EN55022 Class A
Hazardous Area: UL/cUL1604 Class 1 Div 2 (pending)
Transportation Industry: JT/T817-2011; NEMA-TS2 (pending)
Rail Industry:    EN50121-4
Power Industry:  IEC61850-3;   IEEE1613 (C37.90.x)
Industrial Control Industry: UL/cUL61010 
Shipbuilding Industry: GL (pending)

Product Naming
CES2000– DPS1S2S3S4Y
D Description
D Designed for transportation industry
P Network Management
H Layer 2 Modular
W Layer 3 Modular
S1-S4 Port Type & Qty
S1 100/1000M SFP slot (8)
S2 100M FX port (0)
S3 Gigabit TX port (8)
S4 100M TX port (0)
Y Description
P
Support POE
P130 Support POE (built-in 130W power supply)
 
 
Recommended Models
P/N Description
CES2000-PH8000P130
Managed switch, 8 Gigabit POE ports (802.3af/at)+8 100/1000M SFP slots+1 SD card slot, built-in 130W power supply, isolated power supply (100-240V), IP40 protection grade.
CES2000-PH8080 Managed switch, 8 Gigabit TX ports+8 100/1000M SFP slots+1 SD card slot, isolated power supply (100-240V), IP40 protection grade.
CES2000-PW8080 Managed switch, 8 Gigabit TX ports+8 100/1000M SFP slots+1 SD card slot, isolated power supply (18-60VDC), IP40 protection grade.
CES2000-PW8000P Managed switch, 8 Gigabit POE ports (802.3af/at)+8 100/1000M SFP slots+1 SD card slot, isolated power supply (44-57VDC), IP40 protection grade.
Accessories
SFP/XFP Description
MRD-SFP-GLX 100M, single-mode (1310nm), LC connector, 20KM
MRD-SFP-GEX 100M, single-mode (1310/1550nm), LC connector, 40KM
MRD-SFP-GZX 100M, single-mode (1550nm), LC connector, 80KM
MRD-SFP-GSX-850 100M, multi-mode (850nm), LC connector, 2KM
MRD-SFP-GSX 100M, multi-mode (1310nm), LC connector, 2KM
MRD-SFP-GLX-13 100M, single fiber (1310nm TX/ 1550nm RX), LC connector, 20KM
MRD-SFP-GLX-15 100M, single fiber (1550nm TX/ 1310nm RX), LC connector, 20KM
MRD-SFP-GEX-13 100M, single fiber (1310nm TX/ 1550nm RX), LC connector, 40KM
MRD-SFP-GEX-15 100M, single fiber (1550nm TX/ 1310nm RX), LC connector, 40KM
MRD-MGIGA-GTX 1000BASE-T SFP, RJ45 connector, 100M
MRD-MGIGA-GTT 100/1000BASE-T SFP, RJ45 connector, 100M
MRD-MGIGA-GLX Gigabit single-mode (1310nm), LC connector, 20KM
MRD-MGIGA-GEX Gigabit, single-mode (1310/1550nm), LC connector, 40KM
MRD-MGIGA-GZX Gigabit, single-mode (1550nm), LC connector, 80KM
MRD-MGIGA-GSX-850 Gigabit, multi-mode (850nm), LC connector, 550M
MRD-MGIGA-GSX Gigabit, multi-mode (1310nm), LC connector, 550KM
MRD-MGIGA-GLX-13 Gigabit, single fiber (1310nm TX/ 1550nm RX), LC connector, 20KM
MRD-MGIGA-GLX-15 Gigabit, single fiber (1550nm TX/ 1310nm RX), LC connector, 20KM
MRD-MGIGA-GEX-13 Gigabit, single fiber (1310nm TX/ 1550nm RX), LC connector, 40KM
MRD-MGIGA-GEX-15 Gigabit, single fiber (1550nm TX/ 1310nm RX), LC connector, 40KM
MRD-10GLS-LC 10G, single-mode (1310nm), LC connector, 10KM
MRD-10GES-LC 10G, single-mode (1550nm), LC connector, 40KM
MRD-10GZS-LC 10G, single-mode (1550nm), LC connector, 80KM
MRD-10GSS-LC-850 10G, multi-mode (850nm), LC connector, 300M
Installation Accessory Description
SRM1U-HM 19-inch rack mount kit, containing fixing screws
Cable Option Description
PCORDAC-CN-15 1.5m three-core AC power cord, GB plug, 6A rated current
PCORDDC-CN-15 1.5m three-core DC power cable, 200W rated power